p. 8 - Connection to main power supply
ELECTRICAL CONNECTION
The BANDIT 240PB is equipped with simple and yet versatile interface. This version is only
programmable through PC or laptop using the communication link.
This unit is intended to be connected to an existing alarm system or be installed as a stand-alone
unit.
The build-in electronic system takes care of controlling and securing:
- the fog generator (3 x temperature + frequency control of valve).
- tamper switch of the rear cover, HY-3 pack hatch and optional connected "Control Box".
- control of front- and PCB LED, and internal siren.
- read out of inputs and jumper adjustments.
- control of tamper-, technical- and programmable outputs.
- control of internal battery, glass fuses and internal fan.
- digital and analogue communication with the HY-3 pack.
- serial communication with PC/laptop (com port)
The complete electrical system is accessible by removing the rear cover of BANDIT (unscrewing
4 x M4 cross head screw). The rear cover is tamper secured, so be sure that the unit is not in
guard mode and that the control room (optional) is warned.
Connection on the main power supply: on the left, beneath the PCB, you’ll find a
3 way terminal block with integrated main fuse. The PCB is marked with “230 VAC supply”.
Connect the left connector strip (N) to the mains neutral (blue or white wire), the middle one to
the green-yellow ground wire and the right connector (L) to the mains phase (black wire).
Switching phase and neutral has no effect to the function of BANDIT .
The unit is secured for mains failures and can be practically seen as an Ohmic power load.
Connect the power cable through the strain relief connector (~0.5 In. beneath the left entrance in
the metal back frame).
LN
Supply
230 VAC
Power supply
12 V
500 mA
+
-
Power supply glass fuse (5 x 20 mm)
F1 = 4 AT slow
- For complete PCB (printed circuit board) layout with description of connector strips, see page 9.
- For detailed description of
- For properties of the in and outputs, see page 10 through 31.
LED functions, see page 32 through 34.
- Preferably use a separate fuse, directly coming
from the main power supply or connect to
existing power circuit of installed controlling alarm
system (BANDIT has a peak current consumption
of 3.5 Amps. for each unit).
- For easy installing, use flexible connection wires
3 x 1.5 mm² with end splices.
BANDIT 240 PB v.206
F1 4AT